import pytest
|
|
import warnings
|
|
from nucon import Nucon, PumpStatus, PumpDryStatus, PumpOverloadStatus, BreakerStatus
|
|
|
|
WARN_FLOAT_COULD_BE_INT = False
|
|
|
|
@pytest.fixture(scope="module")
|
|
def nucon_setup():
|
|
Nucon.set_dummy_mode(False)
|
|
Nucon.set_base_url("http://localhost:8785/")
|
|
|
|
def test_read_all_parameters(nucon_setup):
|
|
all_params = Nucon.get_all()
|
|
assert len(all_params) == len(Nucon)
|
|
for param, value in all_params.items():
|
|
assert isinstance(value, param.param_type), f"Parameter {param.id} has incorrect type. Expected {param.param_type}, got {type(value)}"
|
|
if param.param_type == float and value.is_integer() and WARN_FLOAT_COULD_BE_INT:
|
|
warnings.warn(f"Parameter {param.id} is a float but has an integer value: {value}")
|
|
if param.param_type == str:
|
|
try:
|
|
float(value)
|
|
raise ValueError(f"Parameter {param.id} is a string that looks like a number: {value}")
|
|
except ValueError:
|
|
pass
|
|
try:
|
|
bool(value.lower())
|
|
raise ValueError(f"Parameter {param.id} is a string that looks like a boolean: {value}")
|
|
except ValueError:
|
|
pass
|
|
|
|
def test_write_writable_parameters(nucon_setup):
|
|
writable_params = Nucon.get_all_writable()
|
|
for param in writable_params:
|
|
current_value = param.value
|
|
param.value = current_value
|
|
assert param.value == current_value, f"Failed to write to parameter {param.id}"
|
|
|
|
def test_non_writable_parameters(nucon_setup):
|
|
non_writable_params = [param for param in Nucon if not param.is_writable]
|
|
for param in non_writable_params:
|
|
# Test that normal set raises an error
|
|
with pytest.raises(ValueError, match=f"Parameter {param.id} is not writable"):
|
|
param.value = param.value # Attempt to write the current value
|
|
|
|
# Test that force_set is refused by the webserver
|
|
current_value = param.value
|
|
with pytest.raises(Exception, match=f"Failed to set parameter {param.id}"):
|
|
Nucon.set(param, current_value, force=True)
|
|
|
|
def test_enum_parameters(nucon_setup):
|
|
pump_status = Nucon.COOLANT_CORE_CIRCULATION_PUMP_0_STATUS.value
|
|
assert isinstance(pump_status, PumpStatus)
|
|
|
|
dry_status = Nucon.COOLANT_CORE_CIRCULATION_PUMP_0_DRY_STATUS.value
|
|
assert isinstance(dry_status, PumpDryStatus)
|
|
|
|
overload_status = Nucon.COOLANT_CORE_CIRCULATION_PUMP_0_OVERLOAD_STATUS.value
|
|
assert isinstance(overload_status, PumpOverloadStatus)
|
|
|
|
breaker_status = Nucon.GENERATOR_0_BREAKER.value
|
|
assert isinstance(breaker_status, BreakerStatus)
|
|
|
|
def test_custom_truthy_values(nucon_setup):
|
|
assert bool(Nucon.COOLANT_CORE_CIRCULATION_PUMP_0_STATUS.value) == (Nucon.COOLANT_CORE_CIRCULATION_PUMP_0_STATUS.value in [PumpStatus.ACTIVE_NO_SPEED_REACHED, PumpStatus.ACTIVE_SPEED_REACHED])
|
|
assert bool(Nucon.COOLANT_CORE_CIRCULATION_PUMP_0_DRY_STATUS.value) == (Nucon.COOLANT_CORE_CIRCULATION_PUMP_0_DRY_STATUS.value == PumpDryStatus.INACTIVE_OR_ACTIVE_WITH_FLUID)
|
|
assert bool(Nucon.COOLANT_CORE_CIRCULATION_PUMP_0_OVERLOAD_STATUS.value) == (Nucon.COOLANT_CORE_CIRCULATION_PUMP_0_OVERLOAD_STATUS.value == PumpOverloadStatus.INACTIVE_OR_ACTIVE_NO_OVERLOAD)
|
|
assert bool(Nucon.GENERATOR_0_BREAKER.value) == (Nucon.GENERATOR_0_BREAKER.value == BreakerStatus.OPEN)
|
|
|
|
def test_get_multiple_parameters(nucon_setup):
|
|
params_to_get = [Nucon.CORE_TEMP, Nucon.CORE_PRESSURE, Nucon.RODS_POS_ACTUAL]
|
|
multiple_params = Nucon.get_multiple(params_to_get)
|
|
assert len(multiple_params) == len(params_to_get)
|
|
for param, value in multiple_params.items():
|
|
assert isinstance(value, param.param_type)
|
|
|
|
def test_base_url_setting():
|
|
original_url = NuconConfig.base_url
|
|
new_url = "http://newlocalhost:9090/"
|
|
Nucon.set_base_url(new_url)
|
|
assert NuconConfig.base_url == new_url
|
|
Nucon.set_base_url(original_url)
|
|
|
|
if __name__ == "__main__":
|
|
pytest.main() |