The previous fix (heat.exe -platform x64) was wrong -- re-verified live with the corrected build.bat confirmed actually deployed to the VM (ruling out a stale-copy repeat of the earlier watcher bug), identical ICE80 "32BitComponent uses 64BitDirectory" failures on every single harvested component. WiX v3's heat.exe -platform flag only affects registry-key harvesting, it never stamps Win64="yes" on components. Real fix: -arch x64 on candle.exe, the compile step, not the harvest step -- sets the default Win64/Platform for every component compiled from either source file (hand-authored product.wxs or harvested files.wxs), the standard WiX v3 way to make a whole package consistently 64-bit. Kept the harmless-but-insufficient heat.exe flag too. Not yet re-verified live -- next run should confirm a real .msi. Co-Authored-By: Claude Sonnet 5 <noreply@anthropic.com>
101 lines
4.1 KiB
Batchfile
101 lines
4.1 KiB
Batchfile
@echo off
|
|
REM Actual per-build packaging. Triggered by watch_build.bat once
|
|
REM install.bat's one-time provisioning has already put MSYS2/GTK4/
|
|
REM libadwaita/WiX in place. Reads source from Z:\src, writes
|
|
REM FEnigma-<version>.msi to Z:\dist, and Z:\BUILD_DONE (or
|
|
REM Z:\BUILD_FAILED, with the log copied alongside it) when finished.
|
|
REM
|
|
REM UNTESTED (see install.bat's note) -- the WiX harvest/link step in
|
|
REM particular is likely to need iteration: bulk-copying all of
|
|
REM mingw64\ is the "make it work first" approach, not a lean one, and
|
|
REM heat.exe's default harvest options may need tuning to actually
|
|
REM produce a working component set for a tree this size.
|
|
|
|
setlocal enabledelayedexpansion
|
|
set LOG=Z:\build.log
|
|
echo [build.bat] starting > %LOG%
|
|
|
|
if exist Z:\BUILD_VERSION (
|
|
set /p APPVER=<Z:\BUILD_VERSION
|
|
) else (
|
|
set APPVER=0.1.0
|
|
)
|
|
echo [build.bat] version %APPVER% >> %LOG%
|
|
|
|
rd /s /q C:\build 2>nul
|
|
mkdir C:\build\src
|
|
mkdir C:\build\dist\src
|
|
mkdir C:\build\dist\mingw64
|
|
|
|
echo [build.bat] copying source from Z:\src ... >> %LOG%
|
|
xcopy /e /i /q Z:\src C:\build\src >> %LOG% 2>&1
|
|
|
|
echo [build.bat] sanity import check ... >> %LOG%
|
|
set PYTHONPATH=C:\build\src\src
|
|
C:\msys64\mingw64\bin\python3.exe -c "import fenigma.app" >> %LOG% 2>&1
|
|
if errorlevel 1 (
|
|
echo [build.bat] FAILED: fenigma.app failed to import, see log >> %LOG%
|
|
copy %LOG% Z:\build.log.failed >nul
|
|
echo FAILED > Z:\BUILD_FAILED
|
|
exit /b 1
|
|
)
|
|
|
|
echo [build.bat] assembling dist tree ... >> %LOG%
|
|
xcopy /e /i /q C:\build\src\src C:\build\dist\src >> %LOG% 2>&1
|
|
REM Bulk-copy the whole mingw64 runtime rather than hand-tracing the DLL/
|
|
REM typelib/icon-theme/schema dependency closure -- bloated (likely 1GB+)
|
|
REM but reliable; trimming this down is a known follow-up, not attempted
|
|
REM here (see this file's top-of-file note).
|
|
robocopy C:\msys64\mingw64 C:\build\dist\mingw64 /e /xd include share\doc share\man share\gtk-doc /nfl /ndl /njh /njs >> %LOG% 2>&1
|
|
|
|
echo [build.bat] harvesting WiX components ... >> %LOG%
|
|
REM -platform x64 alone is NOT enough (confirmed live: still every
|
|
REM component ICE80'd afterward) -- WiX v3 heat.exe's -platform flag
|
|
REM doesn't actually stamp Win64="yes" on harvested components itself,
|
|
REM it only affects registry-key harvesting. Kept anyway (harmless,
|
|
REM correct in spirit), but the real fix is candle.exe's -arch x64
|
|
REM below, see its own comment.
|
|
C:\wix\heat.exe dir C:\build\dist -platform x64 -cg AppFiles -gg -scom -sreg -sfrag -srd -sw5150 -dr INSTALLFOLDER -var var.DistDir -out C:\build\files.wxs >> %LOG% 2>&1
|
|
if errorlevel 1 (
|
|
echo [build.bat] FAILED: heat.exe harvest failed >> %LOG%
|
|
copy %LOG% Z:\build.log.failed >nul
|
|
echo FAILED > Z:\BUILD_FAILED
|
|
exit /b 1
|
|
)
|
|
|
|
copy /y C:\FenigmaBuild\product.wxs C:\build\product.wxs >nul
|
|
|
|
echo [build.bat] compiling (candle) ... >> %LOG%
|
|
REM -arch x64: the actual fix for the ICE80 "32BitComponent uses
|
|
REM 64BitDirectory" failure (confirmed live -- heat.exe's own -platform
|
|
REM x64 above does NOT set this, only affects registry harvesting).
|
|
REM -arch sets the default Win64/Platform for every component compiled
|
|
REM from EITHER source file, hand-authored (product.wxs) or harvested
|
|
REM (files.wxs) alike, without needing per-component authoring -- the
|
|
REM standard WiX v3 way to make a whole package consistently 64-bit,
|
|
REM matching product.wxs's own ProgramFiles64Folder.
|
|
C:\wix\candle.exe -arch x64 -dDistDir=C:\build\dist -dAppVersion=%APPVER% -out C:\build\ C:\build\product.wxs C:\build\files.wxs >> %LOG% 2>&1
|
|
if errorlevel 1 (
|
|
echo [build.bat] FAILED: candle.exe failed >> %LOG%
|
|
copy %LOG% Z:\build.log.failed >nul
|
|
echo FAILED > Z:\BUILD_FAILED
|
|
exit /b 1
|
|
)
|
|
|
|
echo [build.bat] linking (light) ... >> %LOG%
|
|
C:\wix\light.exe -ext WixUIExtension -sice:ICE60 -sice:ICE61 -out C:\build\FEnigma-%APPVER%.msi C:\build\product.wixobj C:\build\files.wixobj >> %LOG% 2>&1
|
|
if errorlevel 1 (
|
|
echo [build.bat] FAILED: light.exe failed >> %LOG%
|
|
copy %LOG% Z:\build.log.failed >nul
|
|
echo FAILED > Z:\BUILD_FAILED
|
|
exit /b 1
|
|
)
|
|
|
|
if not exist Z:\dist mkdir Z:\dist
|
|
copy /y C:\build\FEnigma-%APPVER%.msi Z:\dist\ >> %LOG% 2>&1
|
|
copy /y %LOG% Z:\dist\build.log >nul
|
|
|
|
echo [build.bat] done >> %LOG%
|
|
echo DONE > Z:\BUILD_DONE
|
|